1.4 Error messages
16 780/781 pH/Ion Meter - Operation via RS232
├ .Aux Miscellaneous
│ ├ .RunNo Current run number 0...999, OFF
│ ├ .LastDigit Last digit of display ON, OFF
│ ├ .Language Dialog language english, deutsch, français, español
│ ├ .Display Display type positiv, negativ
│ ├ .ScreenSave Switch LCD display off after [min] 1,2...999, OFF
│ ├ .Set Sets date and time $G
│ │ ├ .Date Current date YYYY-MM-DD
│ │ └ .Time Current time hh:mm:ss
│ ├ .TimeZone Text for time zone 12 ASCII char.
│ ├ .TSensor Type of temperature sensor PT1000, NTC
│ ├ .NTCFactor Factors for NTC sensor
│ │ ├ .NTC25 R(25°C) value 10000...30000...100000
│ │ └
.TSlope Slope, 'B value' 1000...4100...9999
│ ├
.TempUnit Temperature unit °C or °F C, F
│ ├ .DevName Device label 12 ASCII char.
│ ├ .Beeper Number of acoustic signals 1,2,3, OFF
│ └ .Prog Program version number read only
├ .Monitor Monitoring functions
│ ├ .Valid Validation monitoring
│ │ ├ .VState Status of validation monitoring ON, OFF
│ │ ├ .VInterval Time interval for validation [d] 1...365...9999
│ │ ├ .VCounter Time counter [d] 0...9999
│ │ └ .ClearCount Clears the counter above $G
│ ├ .Service Monitoring of Metrohm service $G
│ │ ├ .SState Status of service monitoring ON, OFF
│ │ └ .SDate Date of next service YYYY-MM-DD
│ └ .SysTestReport Printing of system test report ON, OFF
├ .Periph Selection of peripheral units
│ ├ .CharSet Selection of character set IBM, Epson, Seiko, Citizen, HP
│ ├ .Dosimat Selection of Dosimat type 665, 725, 765, 776
│ ├ .SelStirrer Selection of stirrer type 7xx, 8xx
│ ├ .PcKeyb Type of keyboard US, deutsch, français, español,
│ │ schweiz.
│ └ .Barcode Input of barcode reader input, id1, id2
└ .RSset Settings RS232
├ .Baud Baud rate 38400, 19200, 9600, 4800,
│ 2400, 1200, 600, 300
├ .DataBit Number of data bits 7, 8
├ .StopBit Number of stop bits 1, 2
├ .Parity Parity none, odd, even
└ .Ha ndsh Handsh ake HWs, SWchar, SWline, none
&Info
Object Description Input range
&Info Current data
: ├ .Report Transmission of formatted reports $G
│ └ .Select Selection of report type user memory, calib short, calib full,
│ config, param, el.test, result short,
│ result full, mv memory, all
├ .pHCalData pH calibration data
│ ├ .ElectrodeId Identification of calibrated electrode read only
│ ├ .MethodId Name of calibration method read only
│ ├ .Slope Slope [%] 0.1...100.0...999.9
│ ├ .pH0 Electrode zero point -99.999...7.0...99.999
│ ├ .CalTemp Calibration temperature read only